Sign In | Join Free | My uabig.com
China Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd. logo
Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Experts and innovators to solve the thermal control system
Verified Supplier

4 Years

Home > Mineral Insulated Thermocouple Cable >

Metal Mineral Insulated Heating Thermocouple Cable Customsized

Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Metal Mineral Insulated Heating Thermocouple Cable Customsized

Brand Name : LEADKIN

Model Number : LK-KK-φ4.8-SS316-I

Certification : ISO,

Place of Origin : CHINA

MOQ : 100M

Price : USD 0.99-30/M

Payment Terms : L/C, D/A, D/P, T/T

Supply Ability : 1,000,000M/year

Delivery Time : 2-7 working days

Packaging Details : 68*68*8cm Carton

Sheath Material : SS304,SS321,SS316,310S,Inconel600

Type : single,double

Calibration : K,N,E,J,T,R,B,S,Pt100

Dia : 0.5mm-12.7mm

Name : 2 Cores Type K Mineral Insulated Thermocouple MI Cable/Wire

Purity of MgO : ≥99.6%

Sample : free

MOQ : 100M

Package : Carton

Usage : Industrial Temperature test

calibration : K , N, J, T, E, R, B, S

Contact Now

Customized Metal Mineral Insulated Heating Cable Thermocouple Cable

This sheathed mineral-insulated thermocouple wire can be used at high temperatures for prolonged periods with very little drift of the base metal thermocouple. The sheath material uses Nickel-Chrome based sheathing, which provides excellent oxidation resistance. The sheath can withstand long-term exposure to combustion gases or air at temperatures up to1150°C. Short-term exposures to higher temperatures are also possible. Superior resistance to oxidation attack results from a tenacious and protective high temperature film that does not affect the stability of the thermocouple alloys. This film permits the sensor to be used at high temperatures for prolonged periods with improved accuracy over other available sheath materials. The sheathing also provides excellent resistance to corrosion in high temperature chlorine-contaminated oxidizing environments and ammonia/nitride-rich environments at temperatures above 980°C, the temperature at which the protective film forms.

Quick detail

Name:2 Cores Type K Mineral Insulated Thermocouple MI Cable/Wire

Type: K,N,E,J,T,R,B,S,Pt100

Conductor material: NiCr-NiSi, NiCrSi-NiSi), NiCr-Konstantan, Fe-Konstantan, Cu-Konstantan

Insulator: 99.6% high purity MgO

Core number: 2, 4, 6

Sheath material: SS321(SS304), SS316, SS310, Inconel600, Nicrobell

Dia(mm): 0.25mm to 12.7mm

Application: connecting with thermocouple and instrument machine

Place of Origin: Zhejiang, China (Mainland)

Eco-friendly: Yes

MOQ: 100m

Certificate: ISO

Making sample time: all type in stock

Trade term: FOB, EXW, CIF, CFR

Payment term: T/T, Western Union, L/C

Type for Sheath Wire Type K

Product Name Code Type Shaeth Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCrSi-NiSi NK N SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
SS310 Inconel600 0.5-1.0 500
1.5-3.2 800
4.0-6.4 900
8.0-12.7 1000
NiCr-Konstantan EK E SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Fe-Konstantan JK J SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
Cu-Konstantan TK T SS304 SS316 0.5-1.0 400
1.5-3.2 600
4.0-8.0 800
RhPt10-Ph SK S Inconel600 6.0-12.7 1100

Accuracy for Sheath Wire Type K

Type Class I Class II
Accuracy Temp.Range Accuracy Temp.Range
K ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-1000℃ ±0.75% 375℃-1000℃
N ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-1000℃ ±0.75% 375℃-1000℃
E ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-800℃ ±0.75% 375℃-800℃
J ±1.5℃ -40~375℃ ±2.5℃ -40~375℃
±0.4% 375℃-800℃ ±0.75% 375℃-800℃
T ±0.5℃ -40~125℃ ±1.0℃ -40~125℃
±0.4% 125℃-350℃ ±0.75% 125℃-350℃
S 0-1100℃ ±1.0℃ 0-1100℃ ±1.5℃

Product Pictures

Metal Mineral Insulated Heating Thermocouple Cable Customsized

Metal Mineral Insulated Heating Thermocouple Cable Customsized

Order Notice:

1. Accurate quotation.
2. Confirm the price, trade term, lead time, payment term etc.
3. LEADKIN sales send the Proforma Invoice with LEADKIN seal.
4. Customer arranges the payment for deposit and sends us bank slip.
5. Middle Production-send photos to show the production line which you can see your products in . Confirm the estimated delivery time again.
6. End Production-Mass production products photos.
7. Clients make payment for balance and LEADKIN ships the goods. Inform the tracking number and check the status for clients.
8. The order is finished perfectly when you receive the goods and get satisfied with them .
9. Feedback to LEADKIN about Quality , Service, Market Feedback & Suggestion. And we will do better .


Product Tags:

Insulated Heating Cable

      

Inconel600 sheathed Mineral Insulated Cable

      

Pt100 sheathed Mineral Insulated Cable

      
Wholesale Metal Mineral Insulated Heating Thermocouple Cable Customsized from china suppliers

Metal Mineral Insulated Heating Thermocouple Cable Customsized Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)